Abstract

One hundred coagulase-negative staphylococcal isolates from septicemic neutropenic patients with hematologic malignancies were identified to a species level by means of the French API STAPH strip system and by the Automicrobic VITEK system. According to these two methods, which concurred in 95% of cases, S. epidermidis (80-82% of the isolates) was the most frequently identified species, followed by S. haemolyticus (6-7% of the isolates). The susceptibility to oxacillin was also evaluated by macrodilution MIC, Automicrobic VITEK system and agar screen, and 76, 78 and 79 of the 100 isolates, respectively, were found resistant to this antibiotic. All oxacillin-resistant isolates according to Automicrobic VITEK were confirmed resistant by agar screen. A 48h incubation was required to determine oxacillin resistance in 11 of 79 isolates with agar screen and in 10 of 76 isolates with macrodilution MIC. Automicrobic VITEK system may represent a useful method for rapid identification to a species level and early recognition of oxacillin resistance in coagulase-negative staphylococci.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.