Abstract

The separation and preconcentration of vanadium (IV) and vanadium (V) using Sephadex DEAE A-25 with Eriochrome Cyanine R has been studied, based on the preconcentration of vanadium (IV) in the first step and V(V) after reduction with ascorbic acid in the second step. Factors affecting the optimum fixation of the complex were investigated. The absorbance of the solid phase is measured directly at 563 nm for V(IV), at 585 nm for V(V) and at 750 nm for both. The proposed method provides a simple and specific procedure for the separation of vanadium in natural waters. The calibration graph is linear up to 150 ng/mL, with RSD of 4.7% for V(IV) and 4.0% for V(V). The detection limits are 1.6 and 1.4 ng/mL for V(IV) and V(V), respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.