Abstract

We introduce a T-type interface and a crossflow nebulizer to find ways to combine CEC with inductively coupled plasma MS (ICP-MS) detection for selenium speciation. For CEC separation, we employed a macrocyclic polyamine-bonded phase capillary as the separation column and a bare fused-silica capillary filled with the make-up liquid (0.05 M HNO3). The effect of nebulizer gas flow rate, make-up liquid flow, type, concentration and pH of the mobile phase on the separation have been studied. Tris buffer of 50 mM at pH 8.50 gave the best performance for selenium speciation. The reproducibility of the retention time indicated that sample injection by electrokinetic and nebulizer gas flow was better than that by self-aspiration alone. The detection limits for selenate, selenite, selenocystine and selenomethionine were found to be 2.40, 3.53, 12.86 and 11.25 ng/mL, respectively. Due to the high sensitivity and element-specific detection, as well as the high selectivity of the bonded phase, quantitative analysis of selenium speciation in urine was also achieved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.