Abstract

A combined ion chromatography (IC) with inductively coupled plasma mass spectrometry (ICP-MS) system as an element-selective detector has been used for the determination of arsenic compounds. Seven arsenic compounds were separated by cation-exchange chromatography. Subsequently, the separated arsenic compounds were directly introduced into the ICP-MS and were detected at m/z=75. Detection limits for the seven arsenic compounds ranged from 0.8 to 3.8 μg AS/l. The IC-ICP-MS system was applied to the determination of arsenic compounds in the urine of dimethylarsinic acid (DMAA)-exposed rats. DMAA was the most abundant arsenic compound detected. Arsenous acid, monomethylarsonic acid and trimethylarsine oxide were also detected.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.