Abstract
Linear system identification methods based on Laplace transforms and Pade' approximations are used to determine the spatio-temporal responses of a Venlo glasshouse to gaseous enrichment. It is shown that the method for distributing CO 2 in the glasshouse by using a low level ring main with a distribution pipe along the crop rows is adequate for uniform mixing. The analysis also indicates the maximum rate at which the CO 2 set point can be updated dynamically for the proper execution of on-line optimal control of CO 2 .
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.