Abstract

In this paper, we report spatially resolved temperature profiles along the legs of working V-shaped electrothermal (ET) actuators using a surface Raman scattering technique. The Raman probe provides nonperturbing optical data with a spatial resolution of 1.2 /spl mu/m, which is required to observe the 3-/spl mu/m-wide actuator beams. A detailed uncertainty analysis reveals that our Raman thermometry of polycrystalline silicon is performed with fidelity of /spl plusmn/10 to 11 K when the peak location of the Stokes-shifted optical phonon signature is used as an indicator of temperature. This level of uncertainty is sufficient for temperature mapping of many working thermal MEMS devices which exhibit characteristic temperature differences of several hundred Kelvins. To our knowledge, these are the first quantitative and spatially resolved temperature data available for thermal actuator structures. This new temperature data set can be used for validation of actuator thermal design models and these new results are compared with finite-difference simulations of actuator thermal performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.