Abstract

Spatially resolved self-sensing of strain and damage has been shown in carbon fiber cement under flexure by three-point bending. This involves measurement of the one-dimensional distribution of the DC electrical resistance by the use of surface electrical contacts on the bottom (tension) and top (compression) surfaces. For a span of 290 mm, a spatial resolution of 5 mm has been attained. The bottom surface resistance, which increases reversibly with strain and increases irreversibly with damage, is a more effective indicator of strain and damage (in combination) than the top surface resistance, the oblique resistance or the through-thickness resistance for spatially resolved self-sensing. For sensing without spatial resolution, the oblique resistance is the most effective indicator. For sensing with distinction between strain and damage, the top surface resistance is the most effective indicator.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.