Abstract
A measurement set-up is presented containing a multichannel frequency response analyser system together with a multichannel potentiostat that allows measurements of the local electrical impedance spectra of segmented fuel cells simultaneously. For evaluation the current and impedance distribution is combined with optical spatially resolved measurement and numerical simulation. Furthermore the multichannel frequency response analyser system is used for the measurement of impedance spectra of single cells in a fuel cell stack simultaneously.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.