Abstract
The rod system mediated detection of test flashes, but its sensitivity was altered by excitation of the cone system by a concentric background. The magnitude of this rod-cone interaction depended on the diameter of the background field, but in different ways for different observers: large backgrounds caused greater interactions than small backgrounds in two observers, and nearly the opposite spatial pattern occurred in a third. These results were the same with both adjustment and forced-choice procedures, but increasing background illuminance increased the interaction and changed its spatial pattern. We conclude that rod-cone interaction confounds tests of spatial sensitization and contributes to interobserver differences when a red background is used to isolate the rod system. No simple physiological model seems to account for variations in spatial patterns of rod-cone interactions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.