Abstract
Background:Source modeling is an approach to reduce computational burden in Monte Carlo simulations but at the cost of reduced accuracy. Although this method can be effective, one component of the source model that is exceptionally difficult to model is the electron contamination, a significant contributor to the skin and shallow dose.Aims and Objectives:To improve the accuracy for the electron contamination component of the overall source model, we have generated a spatial mesh based surface source model.Methods and Materials:The source model is located downstream from the flattening filter and mirror but upstream from the movable jaws. A typical phase space file uses around ten parameters per particle, but this method simplifies this number to five components. By using only the electron distance from the central axis, angles from the central axis and energy, the computational time and disk space required is greatly reduced.Results and Conclusion:Despite the simplification in the source model, the electron contamination is still accurate to within 1.5%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.