The hardness was found to be lower (by ∼10 in Rockwell H scale) and the volume electrical resistivity was found to be higher (about doubled) at the edge (up to a depth of ∼5 cm for curing at 100% relative humidity) than at the center of a cement mortar specimen prior to loading. This is attributed to the faster drying at the edge and the resulting poorer bond between cement paste and sand at the edge than the center.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.