The spatial distribution of iron incrustations around an abandoned water well after 38 years of use was studied by analyzing the iron content of soil samples from 12 core borings. Three of these were performed inside the gravel pack, the rest at different distances in the adjacent aquifer. Incrustations had preferentially accumulated at the bottom of the screen coinciding with a zone of higher aquifer permeability. As expected, all cores from the annulus show buildup of iron oxides but the ones outside also showed elevated iron content up to 4 m away from the screen. Such distant incrustations are very difficult to remove, by mechanical or chemical methods. The common procedure of removing tubing and annulus material to install a new well at the same location could therefore give the replacement well a hydraulic disadvantage as the incrustations in the aquifer remain in place.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.