In this paper, the experimental data of CO, CO2 and total volatile organic compound (TVOC) concentration in a residential kitchen are presented. Based on them, a simulation software with friendly and simply operating interfaceis is developed on the platform of VC++. The distribution law of the contaminants is studied via the simulation results, and it is obvious that location of accumulation of the contaminants are highly relevant to the location of stove and closer to the walls. An addition natural air makeup system is proposed to improve indoor airenvironment in kitchens, the effection of the air makeup system is analyzed with exergy theory.