Abstract

The calibration of the density of states (DOS) obtained from transient photocurrent (TPC) measurements on PECVD hydrogenated amorphous silicon (a-Si : H) over a wide temperature range is investigated. It is shown that by including a lumped empirical correction to the temperature dependence of parameters such as the free-carrier mobility and capture coefficient, somewhat improved consistency in the DOS calculations may be achieved. The onset of trap saturation is considered as a possible reference point for calibration. Significant differences in the TPC DOS in a-Si : H when using either red or green laser pulse excitations are reported, and are attributed to spatial variations in the defect distribution through the film. Metastable defects produced by exposure of one side of the film to strongly absorbed light are correlated with an increased DOS when probed with the green laser from the same side.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.