Abstract
The results of investigation of luminous intensity distribution and color quantities of LED lamps of different design are presented. It is demonstrated that measurement of angular luminous intensity distribution is more accurately indicates characteristics of LED lamp emission than measured luminous intensity value alongside its mechanical axis. It is established that color quantities of investigated LED lamps declared by manufacturer are different from values defined by applicable normative documents.
Highlights
It is demonstrated that measurement of angular luminous intensity distribution is more accurately indicates characteristics
It is established that color quantities of investigated LED lamps declared by manufacturer are different from values defined by applicable normative documents
Kreidich A.V., junior researcher of Institute of Physics of NAS оf Belarus
Summary
Приведены результаты исследования пространственного распределения силы света и цветовых характеристик светодиодных ламп различной конструкции. Что измерение углового распределения силы света более точно отражает характеристики излучения светодиодных ламп, чем измеренное значение силы света вдоль направления их механической оси. Установлено, что заявленные производителями цветовые характеристики исследованных светодиодных ламп отличаются от норм, установленных действующими техническими нормативными правовыми актами. Ключевые слова: колориметрия, гониофотометрия, пространственное распределение силы света, светодиодные лампы. Гурский А.Л., Крейдич А.В., Машедо Н.В., Никоненко С.В. Пространственные и цветовые характеристики излучения светодиодных ламп.