Abstract

The sparse view problem of image reconstruction encountered in computed tomography (CT) is an important research issue due to its considerable potential in lowering radiation dose. Among the researches, the total variation (TV) method is especially effective in sparse view CT reconstruction for its good ability to preserve sharp edges and suppress noise. However, TV-based methods often produce undesired staircase artifacts in smooth regions of the reconstructed images since the reconstructed problem is usually ill-posed and TV regularization favors piecewise constant functions. Moreover, the image can be accurately approximated by sparse coefficients under a proper wavelet tight frame, which has good capability of sparsely estimating the piecewise smooth functions and the quality of reconstructed image can be improved by the sparse prior information. To deal with sparse view CT reconstruction problem, a minimization hybrid reconstruction model that incorporates TV with the wavelet frame has been proposed, which is to use the TV-norm of the low-frequency wavelet frame coefficients and the $\ell _{0} $ -norm of the high-frequency wavelet frame coefficients to eliminate staircase effect while maintaining sharp edges, simultaneously provide enough regularization in smooth regions. In addition, considering that the two regularization terms produce more parameters, an alternating direction method of multipliers (ADMM) algorithm has been applied to solve the minimization problem by iteratively minimization separately. Finally, compared with several iterative reconstruction methods, the experimental results demonstrate the competitiveness of the proposed method in terms of preserving edges, suppressing staircase artifacts and denoising.

Highlights

  • Reduction of radiation is important in applications of computed tomography (CT)

  • Increasing concerns have emerged with respect to the radiation dose delivered because a high dose of radiation during CT scanning can increase the risk of cancer in patients, especially in children

  • Many efforts have been devoted to reducing this undesired effect

Read more

Summary

INTRODUCTION

Reduction of radiation is important in applications of computed tomography (CT). Z. Qu et al.: Sparse View CT Image Reconstruction Based on TV and Wavelet Frame Regularization angle projection data, the FBP algorithm can reconstruct high-quality images. To address the sparse view CT reconstruction problem, inspired by the advantages of sparse prior information of wavelet frame and protecting the sharp edges of the images of TV while avoiding their disadvantages, a novel reconstruction model is proposed that incorporates TV with the wavelet frame to better reconstruct high quality image, which includes a data fidelity term and two regularization terms. In sparse view CT reconstruction, due to the incompleteness of the sparse projection data and the TV regularization favors piecewise constant functions, the traditional TV-based method generates staircase artifacts and cannot effectively suppress the heavy noise. The proposed minimization model based on the wavelet frame and TV regularization are utilized to achieve higher quality images for sparse view CT reconstruction

MODEL AND NUMERICAL ALGORITHM
EXPERIMENT AND ANALYSIS
Findings
CONCLUSION
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call