Abstract

Vacuum ultraviolet (VUV) and soft X-ray (SX) spectroscopic measurements are important means to diagnose radiation power loss, impurity ion densities and effective charge of confined plasma, Z eff , in magnetically confined plasmas such as fusion plasmas. We have constructed space- and time-resolving flat-field VUV (150–1050Å) and SX (20–350Å) spectrographs by using aberration-corrected concave gratings with varied line spacing. Absolute calibration experiments have been conducted at the Photon Factory in the High Energy Accelerator Research Organization. Absolute sensitivities of the VUV and SX spectrographs have been obtained for the two (S and P) polarization geometries. Thus, absolute intensities of emission spectra from impurity ions can be measured together with their radial distributions in plasmas. The total radiation power was determined to be less than 6 kW within ±20% of error in our normal plasma operation. Density profiles of impurity ions were reduced by using absolute emissivities of impurity lines and a collisional-radiative model. Moreover, the value of Z eff is estimated to be 1.00 in the tandem mirror GAMMA 10 plasma.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.