Abstract

The results of space charge evolution in cross-linked polyethylene power cables under dc electrical field at a uniform temperature and during external voltage polarity reversal are presented in the paper. A mirror image charge distribution was observed in the steady state, but the pre-existing field altered the way in which the steady state charge distribution was formed from that obtaining when the cable was first polarized. Polarity reversing charge was generated in the middle of the insulation and moved towards the appropriate electrodes under the influence of a field in excess of the maximum applied field. Our results show that the mirror effect is a steady state effect that is due to cross-interface currents that depend only on the interface field and not its polarity. Measurements on cable sections with an elevated mean temperature and temperature gradient show that the interface currents are temperature dependent, and that differences between the activation energies of the interface and bulk currents can eliminate, and possibly even invert the polarity of the space charge distribution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.