Abstract

This paper discusses the SOx reduction by feedwater in an industrial boiler. The combustion and fluid flow in the boiler is examined with emphasis on the effect of feedwater on SOx reduction. The simulation results indicate that feedwater injected into the DeSOx section has little influence on the heat absorption of the cooling pipes in the flue gas cooling section. The boiler exit temperature and the exit concentrations of SOx, NOx and CO are reduced by the feedwater. When the feedwater flowrate is increased to 1000 times the original value, the boiler exit temperature and the exit concentrations of SOx, NOx and CO are reduced to 1/2, 1/13, 1/13 and 1/20 of the original values.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.