Abstract

Sound velocity and attenuation measurements have been made in bubble clouds comprised of water and air. It has been known for some time that the sound velocity in a bubbly liquid is less than that of either the gas or liquid phase (e.g., 70 m/s at 2% void fraction for air bubbles in water). Standing-wave and time-of-flight methods in cylindrical tubes were used. A standing-wave technique patterned after Silberman [J. Acoust. Soc. Am. 29, 925 (1957)] was used to measure sound velocity at low void fractions (<2%). In this work, more attention was given to the problem of obtaining a more uniform bubble size distribution which was not present in Silberman’s experiment. To achieve this, hypodermic needles were used to produce a reasonably nondispersive bubble size distribution within the cloud. Also, time-of-flight measurements were made at pulse frequencies well below the bubble resonance to observe the dependence of high void fraction (≳10%) on sound velocity and attenuation. [Work supported by ONR.]

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.