Abstract

A series of experiments was conducted in the present study in an attempt to understand how the implementation of active noise control would affect the sound transmission across a plenum window. A simple squared pressure control scheme with three error sensors equi-spaced on the vertical centerline of the indoor window opening was adopted. The secondary control loudspeakers were fixed close to the outdoor window opening. The effects of secondary control loudspeaker orientation relative to the plenum cavity and their locations on the performance of the active control were investigated. Results show that the active control system with two loudspeakers located symmetrically about the plenum cavity horizontal centerline facing directly the incoming noise gives the best performance. However, the effective frequency range is restricted to that below the first asymmetric mode cut-off frequency in the window gap direction. The active control performance is improved when the reverberation strength of the receiver chamber is reduced in general.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.