Abstract

BackgroundFrom quiet environment in uterus, neonates in special care newborn units (SCNU) get exposed to a stressful technology-driven environment. Noise level in neonatal intensive care units (NICU) depends on social and psychological realm of people working there. In NICU, an hourly Leq (median equivalent continuous sound level) of sound should be 45 dB, Lmax, 60 dB, and L10 not exceeding 50 dB (AAP, 2007). Noise level in SCNUs of northeast India has not been studied.AimCreate awareness among health workers (HW) regarding noise.ObjectiveTo study (a) noise level in special care newborn unit and (b) its effect on neonatal physiology.MethodologyA prospective observational study was conducted in a teaching hospital in northeast India for 1 month. After IEC approval, ambient sound levels in intensive care unit (ICU) (levels 2 & 3) and kangaroo mother care (KMC) area were measured using inVH by Bosch Engineering Solution (android app) in 3 shifts. Forty hemodynamically stable quiet low birth weight neonates (level 2: 16, level 3: 14, KMC: 10) were evaluated for heart rate and respiratory rate at same time. Acutely sick neonates were excluded. Statistical analysis was done using SPSS.ResultsAverage sound at 10 am, 5 pm, and 11 pm in level 2 was 70.2 (+ 3.78) dB, 71.9 (+ 4.21) dB, and 54.6 (+ 5.38) dB; in level 3: 66.4 (+ 3.71) dB, 64.9 (+ 3.88) dB, and 63.5 (+ 2.52) dB; and KMC: 55.06 (+ 5), 54.66 (+ 5.38), and 47.7 (+ 5.1) dB (p = 0.0052). Of included neonates, mean birthweight in intensive vs KMC area was 1.378 (+ 0.017) vs 1.337 (+ 0.02) kg (p = 0.1) and gestational age 35.45 (+ 0.25) weeks and 34.8 (+ 0.91) weeks (p = 0.2). The mean neonatal heart rate and respiratory rates in level 2 were 154/min and 44 cycles/min, level 3: 148/min and 47 cycles/min; and KMC: 124/min and 40 cycles/min.ConclusionSignificant noise pollution is detected in levels 2 and 3 neonatal intensive care units and minimal in kangaroo mother care area. Raised neonatal heart rates and respiratory rates in intensive care units with respect to KMC area may be related to noise. The social and psychological realm of healthcare workers and caregivers needs urgent improvement so as to reduce ambient noise pollution in special care newborn units.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.