Abstract

The sound attenuation characteristics of the audiometric earphone Telephonics TDH-39 with cushion MX-41/AR have been tested, using the hearing threshold method according to the International Standard ISO 4869-1981 ("Acoustics--Measurement of sound attenuation of hearing protectors--Subjective method"). This method specifies 1/3-oct bands of noise as test signals and a diffuse sound field. This is in contrast to the use of pure tones in a frontally incident free sound field, by means of which most earlier attenuation data have been obtained. The mean sound attenuation values obtained from a group of 20 normal-hearing subjects were up to 3-5 dB lower than those previously reported for pure tones in a free field.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.