Abstract

An inexpensive and effective sample preparation procedure for the determination of three ethylphenolic off-flavours (4-ethylphenol, 4-ethylguaiacol and 4-ethylcathecol) in wine samples is presented. Analytes were in situ acetylated and concentrated using a disposable silicone sorbent (DSS) exposed to the diluted sample. After that, the analytes were recovered with ethyl acetate and determined by gas chromatography with mass spectrometry. The influence of different parameters (volume of acetic anhydride, basic catalyst, ionic strength, sorbent format, sampling mode and extraction time) on the efficiency of derivatization and extraction steps is discussed. Under optimized conditions, 2 mL of wine were diluted with 15 mL of an aqueous solution of potassium bicarbonate (5%, m/v) in a 22 mL vessel, containing 2 g of sodium chloride. The volume of acetic anhydride and the extraction time were set at 90 μL and 2 h, and the extraction was carried out at room temperature (20 ± 2 °C). Analytes were concentrated using a silicone disc (5 mm diameter × 0.5 mm thickness) and further desorbed with 0.2 mL of ethyl acetate. The achieved limits of quantification (LOQs), defined as the concentration of each compound providing a signal 10 times higher than the baseline noise, stayed between 5 and 15 ng mL −1. The method provided a linear response range of up to 5000 ng mL −1 and relative recoveries from 91% to 116%. The 4-ethylphenol off-flavour was detected in most red wine samples at concentrations of up to 2700 ng mL −1.