Abstract

AbstractBatch experiments were performed to evaluate the ability of spent grain to remove chromium (VI) from aqueous solution. Parameters investigated include pH, contact time, sorbent dosage, agitation rate, and the presence of other anions. Application of the Langmuir isotherm to the Cr(VI)–spent grain system provided a maximum sorption capacity of 18.94 mg/g. This value compares favorably with other reported values for low‐cost materials. Anions such as phosphate, arsenate, nitrate, and sulfate were antagonistic toward the uptake of Cr(VI) by spent grain. It was successful in removing Cr(VI) from a sample of electroplating waste. © 2001 John Wiley & Sons, Inc. J Appl Polym Sci 82: 2128–2134, 2001

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.