Abstract

A solid-phase microextraction (SPME) method based on a sampler coating that includes strong cation groups (C18/SCX) is explored as a rapid direct sampling tool to detect and quantify freely dissolved basic drugs. Sampling kinetics, sorption isotherms and competitive effects on extraction yields in mixtures were tested for amphetamine and the relatively large/hydrophobic tricyclic antidepressant amitriptyline. Both compounds are >99% ionized at pH 7.4 but their affinity for the C18/SCX fiber is markedly different with distribution coefficients (Dfw values) of 2.49±0.02 for amphetamine and 4.72±0.10 for amitriptyline. Typical changes in electrolyte homeostasis that may occur in biomedical samples were simulated by altering pH and ionic composition (Na+ and K+ concentrations). These changes were shown to affect C18/SCX sorption affinities of the tested drugs with less than 0.2log units. At relatively low fiber loadings (<10mmol/L coating) and at all tested exposure times, linear sorption isotherms were obtained for both compounds but at aqueous concentrations of the individual drugs corresponding to concentrations in blood that are lethal, sorption isotherms became strongly nonlinear. Competition effects within binary mixtures occurred only if combinations of aqueous concentrations resulted in total fiber loadings that were in the nonlinear range of the SPME sorption isotherm for the individual compounds. We also compared sorption to the (prototype) C18/SCX SPME coating with analogue (biocompatible) C18 coated SPME fibers. C18/SCX fibers show increased sorption affinity for cationic compounds compared to C18 fibers, as tested using amitriptyline, amphetamine and trimethoprim. Surprisingly, sorption affinity of these ionized compounds for the C18 SPME fibers were within 1log unit of the C18/SCX SPME fibers. This shows that the strong cation exchange groups within the C18/SCX coating only has a relatively small contribution to the total sorption affinity of cationic compounds. Also the role of negatively charged silanol groups in both the C18 and C18/SCX coating seems small, as anionic diclofenac species sorbed strongly to the C18 fiber. Ionized organic species seem to be substantially adsorbed to the high surface area of C18 in SPME types using porous silica based coatings.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.