Abstract

Summary A programme of tests was undertaken of concrete prisms in axial compression to study the influence of the static strength and the maximum size of coarse aggregate upon the fatigue strength at one million cycles. Four types of concrete were tested having average static strengths of about 6,000 and 8,500 lb/in2, each made with aggregate of ¾ and ⅜ in. maximum size. The fatigue strength varied between 66 and 71 % of the static strength and, although the percentage values were significantly lower with the higher-strength concrete and with the ⅜ in. aggregate, the actual magnitude of the differences was small. The general strain history was typical of previous fatigue tests, and the ‘run-out’ specimens showed a marked increase in static strength over similar specimens that had not been loaded.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.