Abstract The errors due to the use of the approximation Icorr′ = B′ΔI, where B′ depends on anodic and cathodic Tafel slopes, in commercial corrosion current meters is shown to be due to the nonlinearity of the current-potential curve in the vicinity of the corrosion potential. These errors are calculated for various combinations of Tafel slopes. It is proposed to use the relationship Icorr = κΔI, where κ depends on Tafel slopes, sign, and magnitude of polarization. The values of κ are tabulated for various combinations of Tafel slopes and polarization of +10 and −10 mV. The proposed procedure leads to correct values of corrosion currents independent of the degree of nonlinearity of the polarization curve.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.