Abstract

A systematic investigation was made of the differences in atomizing performance between water and kerosene fuel for six simplex fuel nozzles of small flow capacity. A large number of tests was run using two methods of spray analysis, to determine the effect of nozzle liquid pressure drop (ΔPF) on Sauter Mean Diameter (SMD). It was found that there is a clearly-defined relationship dependent on both the relative values of surface tension and also on a Weber Number calculated for conditions in the liquid film at the nozzle discharge orifice. It is concluded that large errors in estimating SMD for modeling programs are possible if results observed with water are assumed to be representative of behavior with kerosene fuel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.