Abstract

Abstract To attain the maximum separation of the steroid impurities in pharmaceutically important synthetic corticosteroids the running of two or more chromatograms using different solvent systems is recommended. Using adsorption chromatography, solvent systems of the type 1,2-dichloroethane: methanol:water, 95:5:0·2, give the most satisfactory general separations. Some steroids can best be separated by partition chromatography, using formamide as the stationary phase and chloroform:ether:water, 80:20:0·5, or cyclohexane:tetrachloroethane:water, 50:50:0·1, as the mobile phase. A spray reagent of 0·05% tetrazolium blue and 8% sodium hydroxide in methanol is recommended. The amounts of foreign related steroids can be limited by running standard amounts of impurities alongside the steroid under test and comparing the colour intensities of the impurities in the steroid with those of the standards.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.