Abstract

Somatostatin-like immunoreactivity (SLI) concentrations were determined in human peripheral plasma using affinity chromatography followed by radioimmunoassay. In normal subjects, fasting SLI ranged from 2.9 to 22.0 pg/ml with a mean +/- SE value of 10.2 +/- 2.1 pg/ml. In totally pancreatectomized or gastrectomized patients, fasting SLI levels were not different from the values in normal subjects. In patients with medullary thyroid carcinoma, fasting SLI ranged from 11.8 to 71.0 pg/ml with a mean of 29.3 +/- 12.3 pg/ml, which was significantly higher than normal values (P less than 0.01). Following meal ingestion, plasma SLI increased significantly in normal subjects from a basal level of 9.1 +/- 2.1 pg/ml to a peak value of 15.4 +/- 2.9 pg/ml (P less than 0.02). These results indicate that radioimmunoassay combined with affinity chromatography provides an accurate method of measuring SLI in human plasma.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.