Abstract

This paper addresses a technique to solve the problem of accumulated heat transfer in solenoid coil of the solenoid valve controlling hydraulic damper by using the switching technique with low frequency. This new method can result in saving the energy loss in solenoid coil. In addition, this technique aims to solve the fundamental problem by reducing direct heat transfer in solenoid coil of the solenoid valve and protecting complete gas turbine trip from the hydraulic damper closing failure and heat recovery steam generator (HRSG) trips from burnt solenoid coil of hydraulic damper. For this experiment and research, the data was collected from South Bangkok Combined Cycle Power Plant Block II. After using low frequency switching circuit technique the gas turbine trip as well as the HRSG trip did not happen.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.