Abstract Presents review for guidance of present-day operators of anhydrous hydrogen fluoride alkylation process. Covers early laboratory and pilot plant tests and metallurgical problems encountered in first commercial units. Steel was recognized early as a material for contruction of principal components of process units but was not satisfactory for all services. Monel, ruled out initially, later was found satisfactory for service as trim and in various kinds of valves. Valves with steel cocks failed when the HF attacked them, often sealing them into inoperable condition. Grease used for lubrication was troublesome in the stream. Numerous kinds of packing were tried, but none were entirely satisfactory at first. Monel and fluorocarbons made available later solved packing and valve-seat problems and also problem of protecting glass sight level gauges. Steel bolts failed rapidly from stress corrosion cracking when small leaks resulted in acid attack. K-Monel bolts also failed. Duranickel bolts were satisfa...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.