Abstract

AbstractConventional extraction equipment has many problems like a long mixing time, a large factory area occupation, a large amount of organic solvent consumption and so on. In this paper, a micro solvent extraction system for the extraction of Nd(III) was investigated to solve the above issues. The initial aqueous pH 4.0 and saponification rate 40% of 2-ethylhexyl phosphoric acid-2-ethylhexyl ester (P507) were selected as the optimal experimental conditions. The extraction equilibrium was quickly achieved within 1.5 s, without any mechanical mixing in a narrow channel (100 μm in width and 120 μm in depth) at a volumetric flow rate from 5.55×10