Abstract

The paper discusses various familiar and new process combinations of multi-stage-flash (MSF) and mechanical vapour compression (MVC) distillation. Coupling of an MVC distiller to an MSF unit considerably reduces the consumption of energy and chemicals as well as feed water requirements. The plant is extremely flexible with respect to partial load operation and adaption to varying availabilities of thermal and electrical energy. An existing MSF distiller with a capacity of up to 2000 m 3/d can be extended by coupling it with a simplified MVC module. Investment and operation costs are notably lower than with the installation of additional MSF units.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.