Abstract

In order to achieve accurate detection and evaluation of the freshness of fish samples, high sensitivity and selectivity of histamine sensors based on solution-gated graphene transistors (SGGT) have been successfully developed. By using graphene (Gra), multi-walled carbon nanotubes (MWNT) and gold nanoparticles (AuNP) to functionalize the gate electrode, the electrocatalytic performance of the device can be significantly improved. We have found that graphene, MWNT and AuNP modified SGGT sensors exhibit an ultra-low detection limit of 100 nM for histamine, a linear range of 3 μM–100 μM. We have also demonstrated that the SGGT-based histamine sensor has a high recovery rate and is capable of assessing the histamine content of actual fish samples in a fast and accurate manner. Considering the superior performance of the SGGT-based histamine sensor, it can be readily extended to histamine determination in many other real food samples for their freshness assessment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.