Abstract

To date, PD-L1 expression in tumor tissue, assessed by immunohistochemical stain, is clinically applicable as a predictive companion biomarker for PD-1/PD-L1 inhibitor which has been highlighted over the past several years. Before blood-based sPD-L1 enters clinical use, it is critical to establish the reference range. This study was designed to investigate soluble sPD-L1 levels in various cancer patients and normal population. For the detection of sPD-L1, 4 cancer groups (hepatocellular carcinoma, lung cancer, bladder cancer, gastric cancer) and healthy volunteers' samples were analyzed using an ELISA kit. Using a receiver operating characteristic curve, optimal sPD-L1 cutoff levels were determined. The mean serum sPD-L1 level of the normal population was 59.97 pg/mL (range; 23.780 - 115.2 pg/mL). In various cancer types, serum sPD-L1 levels ranged from 38.696 pg/mL to 228.77 pg/mL, and cutoff values under AUC ranged from 60.307 pg/mL to 64.371 pg/mL. sPD-L1 can be used as a screening biomarker in various cancer patients referring to optimal cutoff levels suggested.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.