Abstract
Solid-state pulsed power technology has been successfully applied to a high average power dense plasma focus (DPF) x-ray point source. In the past, electrode erosion and the associated insulator lifetime have been the primary limiting factors for implementing a DPF x-ray source in a practical x-ray lithographic tool. The solid-state pulsed power supply described here uses fast-switching thyristors, diodes, and saturable magnetics to eliminate current reversal through the DPF electrodes. This has improved the DPF system performance and lifetime by reducing the electrode and insulator vaporization rates more than 20× compared to conventional sparkgap-switched drivers. Erosion measurements indicate that an electrode set can last more than 5 million shots before refurbishment. The DPF source produces an average energy of 7.3 J pulse into 4π Sr at a 1.1 keV effective wavelength in ∼1 Torr of neon gas at repetition rates up to 60 Hz. The x-ray yield efficiency is nominally 0.6%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.