Abstract
A method for preconcentration of trace heavy metal ions in environmental samples has been reported. The presented method is based on the sorption of Cr3+, Co2+, Cu2+, Fe3+, Ni2+, and Zn2+ ions with 2-(2,4-dichlorobenzylideneamino) benzenethiol as respective chelate on modified Duolite XAD 761. The metals content of the sorbed complexes are eluted using 6ml of 4M nitric acid. The influences of the analytical parameters including pH, amount of ligand and solid phase and condition of eluting solution, the effects of matrix ions on the retentions of the analytes were examined. The recoveries of analytes are generally higher than 94% and the RSD is between 1.5% and 2.2%. The method has been successfully applied for the evaluation of understudy metals content in some food samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Food and Chemical Toxicology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.