Abstract

Direct comparison between fluorescence spectra of a sample in solution and solid state form is valuable to monitor the changes in protein structure when it is "dried" or immobilized on a solid surface (for biocatalysis or sensor applications). We describe here a simple method for recording fluorescence emission spectra of protein powders without using any dedicated accessory for solid samples in a high-throughput format. The 96-well plate used in our studies, was coated black from all the sides and the excitation and emission paths are identical and are from the top of the well. These two features minimize scatter and provide fairly noise free spectra. Even then the fluorescence intensity may be dependent upon many factors such as the extent of protein aggregation, morphology and sizes of the protein particles. Hence, (changes in) λ max emission may be a more reliable metric in the case of fluorescence spectra of proteins in the solid state. However, any large changes in the intensity could indicate changes in the microenvironment of the fluorophore. The fluorescence emission spectra were blue-shifted (4 to 9 nm), showed an increase in the intensity for different proteins studied upon lyophilization, and were similar to what has been reported by others using available commercial accessories for solid state samples. After validating that our method worked just as well as the dedicated accessories, we applied the method to compare the fluorescence emission spectra of α-chymotrypsin in solution, precipitated form, and the lyophilized powder form. We further examined the fluorescence emission spectra of green fluorescent protein (GFP) in solution and solid form. We also analyzed fluorescence resonance energy transfer (FRET) between tryptophan (Trp57) and the cyclic chromophore of GFP. These findings pointed towards the change in the microenvironment around the cyclic chromophore in GFP upon lyophilization.

Highlights

  • Fluorescence spectroscopy is a powerful tool to study protein structure[1,2,3]

  • It was used to track changes in fluorescence spectra of green fluorescent protein (GFP) when it is dried. While the former application is relevant to non-aqueous enzymology, the latter provides some insight into fluorescence resonance energy transfer (FRET) between tryptophan of GFP (Trp57) and its cyclic chromophore[20,21]

  • Intrinsic fluorescence emission spectra of four different commercial proteins were obtained after lyophilization from the aqueous buffer and compared with the spectra of the respective protein in the aqueous buffer solution (Figure 1)

Read more

Summary

METHOD ARTICLE

Solid state fluorescence of proteins in high throughput mode and its applications [version 2; peer review: 2 approved].

11 Mar 2013 report report
Introduction
Results and discussion
Conclusion
Lakowicz JR
12. Gupta MN
19. Horiba Jobin Yvon Florescence Technical Note FL-6
23. Tsien RY

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.