Aim: Determination of plasma protein binding (PPB) is considered vital for better understanding of pharmacokinetic and pharmacodynamic activities of drugs due to the role of free concentration in pharmacological response. Methodology &results: Solid-phase microextraction (SPME) was investigated for measurement of PPB from biological matrices and compared with a gold standard approach (rapid equilibrium dialysis [RED]). Discussion & conclusion: SPME-derived values of PPB correlated well with literature values, and those determined by RED. Respectively, average protein binding across three concentrations by RED and SPME was 33.1 and 31.7% for metoprolol, 89.0 and 86.6% for propranolol and 99.2 and 99.0% for diclofenac. This study generates some evidence for SPME as an alternative platform for the determination of PPB.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.