Abstract

Eleven cytokinins-including bases, ribosides, glucosides, and ribotides-were tested for their retention on C18 cartridges that were washed with 40 mL of water or a dilute acid at pH 3. Cytokinins were then eluted with methanol and analyzed by high performance liquid chromatography (HPLC). All pure cytokinin were well retained when the cartridge was washed with water, but Z and (diH)Z were less well retained at pH 3. The ribotides required 80% methanol for elution. Cotton leaf tissue (500 mg dry wt) was spiked with cytokinins, extracted with 80% methanol, and the extract bulk purified with hexane, insoluble polyvinylpyrrolidone, and minicolumns (strong anion exchange, amino, and C18 cartridges). Ribotides, added to leaf tissue, could not be recovered as ribotides; it was necessary to hydrolyze and purify them as ribosides. The cytokinins were separated and analyzed by HPLC on strong cation exchange and C18 columns. Recoveries through the entire procedure averaged 70%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.