Abstract
Extracts of tomato samples, obtained using acetone solvent followed by liquid–liquid partition with a mixture of dichloromethane and light petroleum (40–60°C), were subjected to cleanup with solid-phase extraction (SPE) columns for the simultaneous multiclass determination of 12 pesticides with different physicochemical properties (log P ow = 0.7 to > 6). Silica, aminopropyl (NH2), graphitized carbon black (GCB), octadecyl (C-18) with GCB and the mixed-mode SAX/PSA (SPE) columns were evaluated. The sample cleanup provided by these columns was evaluated using gas chromatography with electron capture detection. The mixed-mode SAX/PSA columns were found to provide the most effective cleanup, along with the (NH2) columns, removing the greatest number of sample matrix interferences. The GCB sorbents also remove pigments but do not remove noticeable chromatographic interferents. The silica columns did little to eliminate the matrix effect for the compound dimethoate. Likewise, the C-18 in combination with the GCB sorbents did little to eliminate matrix interferences.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Environmental Analytical Chemistry
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.