Abstract

ABSTRACTIn this study, a simple and efficient solid phase extraction procedure was developed for simultaneous separation and preconcentration of Ba, Cd, Co, Cu, Mn and Ni. The methodology was based on preconcentration of the target analytes on N,N’-bis(4-methoxysalicylidene)-1,3-propanediamine modified silica gel prior to inductively coupled plasma optic emission spectrometry detection. The experimental conditions were as follows: pH of sample 5.00; sample and eluent flow rates 3 mL min−1; sample volume 25 mL; eluent 0.5 mol L−1 HNO3; eluent volume 3.0 mL. Preconcentration factor was achieved as 33.3 for Ba, Co, Mn; 83.3 for Cd, Ni; 166.7 for Cu. Limits of detection were found as 0.33, 0.26, 0.27, 0.36, 0.27 and 0.19 µg L−1 for Ba, Cd, Co, Cu, Mn and Ni, respectively. The relative standard deviations of 2.6–3.8% were obtained via nine parallel analyses. The suggested procedure was successfully validated by the analysis of TMDA-53.3 Lake Ontario water and ERM-CA022a soft drinking water certified reference materials and applied to various natural water samples.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.