Abstract

In parallel to the stationary solid oxide fuel cell stack tests (>34,000 h), a long-term test with a two-layer solid oxide electrolyzer stack comprising JÜLICH’s F10 design was carried out. The stack was mainly characterized in a furnace environment in electrolysis mode, with 50% humidification of H2 at 800 °C. The endothermic operation was carried out with a current density of -0.5 Acm-2 and steam conversion rate of 50%. Electrolysis at lower temperatures (i.e., 700 °C and 750 °C) and fuel cell operation (with 0.5 Acm-2 and fuel utilization of 50%) at 800 °C were also carried out for short durations (<2000 h each) for comparison. After ~21,000 hours of operation in total, the voltage and ASR degradation rates during electrolysis at 800 °C (8000-20,000 h) were ~0.4%/kh and 2.7%/kh, respectively. In this work, stack performance and degradation analysis under different working conditions is presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.