Abstract

Airborne contaminations on telescope mirrors are an important issue that is significantly affecting their reflectance, IR emissivity, and light scattering properties. Microscopic damage caused by environmental contaminants is of major interest for high-performance telescope mirror coatings. We have exposed unprotected Al coated mirrors under real operation conditions at the Very Large Telescope on Cerro Paranal/Chile for three years. The unique finding is that, in spite of a dry and low-dust environment, the reflective layers are damaged by interaction between dust particles on the Al mirror surface and capillary condensation. We analyze this particular damage mechanism at the microstructural level.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.