Large oil tanks are sufficiently flexible to transmit their liquid load to the foundation with little structural interaction. Modes of failure and measured distortions of successful tanks have indicated acceptable deformations for the floors and shells of tanks. The cheapest form of foundation is a pad of compact fill placed directly on the stripped ground surface. When the soil is initially too weak to support the weight of a full tank, it may be consolidated by a surcharge of random fill before the tank is built, or by the weight of the tank itself during initial controlled loading. When this method is used, settlement may be reduced and stability improved by placing a temporary bund to load the soil just outside the tank. This paper describes eight case histories of failures of tanks on pad and piled foundations and gives several examples of the observed distortions of tanks in service. Methods that have been used to limit differential settlements are discussed and limits are given for acceptable differential settlements under tank floors and shells. The paper concludes with design guidance notes. /Author/

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.