Abstract

Biofilter technology has been applied recently to treating rendering odors. Soil beds are one class of biofilter but as yet have not been used for this application. Although wet scrubbers have been a traditional method of odor control, their capital and operating costs are impacting more severely. Soil bed systems are less expensive to install and operate. A soil bed system was installed at a rendering plant in Arizona and has been in operation since September 1983. The soil bed treats 1100 m3/h (650 cfm) of cooker noncondensables with a surface area of 420 m2(4500 ft2). The pressure drop across the soil bed is 5 cm (2 in.) of water. Odor sensory testing with the MTRI forced-choice triangle dynamic olfactometer indicates an odor removal efficiency of 99.9 percent is obtained with the soil bed. Soil bed odor removal efficiency is equivalent to or superior than that for incineration or scrubbing of high intensity odors from the rendering process. Recent experience during this past winter indicates a soil be...

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call