Abstract

Lightning protection system protects building structure from direct lightning impact. Embedding lightning protection cable inside concrete structure is widely use in practice now days. The objective of this research is to investigate the effect of installation of additional conductor cable inside concrete beam to its beam displacement and beam stress using finite element analysis software ABAQUS. The beam without additional conductor cable, with cable conductor installed at top and bottom reinforcement is modelled using ABAQUS. The results obtained from the three model is compared. As the result, the beam with additional conductor cable at top reinforcement shows minimum deformation and minimum Mises stress.