Abstract
The chemical modifications introduced in the passive layer of AISI 304 stainless steel after Si, Ce, and Mo ion implantation were investigated and compared with non-implanted steel by soft X-ray absorption spectroscopy. The influence of ion implantation on the passive properties was evaluated by measuring soft X-ray absorption spectra at the Cr, Fe, Ni, Mn and Si 2p in addition to oxygen 1s thresholds. All ion implanted samples show a relative Cr-enrichment at the surface as compared with non-implanted samples. Fe 2p as well as O 1s spectral changes reveal chemical differences in the passive layer as a function of the element ion-implanted.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.